Key Features

· 6th Gen Intel Core i3 CPU
· DDR4 Memory
· 90 to 264V AC Power Input
· MIL-STD-810G Shock & Vibration
· EN 60950-2006 +A2:2103 Safety
· TEMPEST SDIP 27 (Level B)

Downloads


Quick Overview

Designed to meet TEMPEST standards SDIP 27 (Level B), the TR-1000 encompasses a powerful specification that ensures protection against unintended electromagnetic emission.


Contact Us

Please email or call 01527 512400 for a quote

Product Code

TR-1000

CPU Options

6th Generation Intel Core i3 Processor (2.7GHz)

Memory

8GB DDR4 Memory

Storage

128GB SSD

Optical Drive

DVD RW Drive (Behind Screened Access Panel)

I/O Interface

Main Input (IEC 60320 C14)
M6 Earth Stud
2 x USB 2.0 (Type A Connectors)
VGA (15 Way High Density D Socket)
2 x LAN (RJ-45 Sockets—10/100/1000)

Front Panel Controls

Power Button (Illuminated)
Reset Switch

Power Input Range

90 – 264V AC, 3 / 1.5A, 47 – 63Hz

Power Consumption

Idle (Desktop):
35W

100% CPU Load:
56W Max

Dimensions (D x W x H)

530mm x 430.5mm x 43.66mm (Excluding Handles)

Weight

Approximately 5.6kg

Safety

BS EN 60950-2006 +A2:2013

Environmental

Packaged:
-10°C to +70°C up to 95% RH

Operational:
0°C to +50°C, 30% – 75% RH

Pressure:
Operational 80mbar Above Standard Atmospheric Pressure

Vibration

In Accordance With MIL-STD 810G Method 514.7; 4.5.2 Procedure 1 – General Vibration

Packaged:
5Hz to 150Hz, Lesser of +/-6mm or +/-2g, 3 Mutually Perpendicular Axes,
1 Octave / Minute, 2 Hours In Each Axis.

Operational:
5Hz to 33Hz, 0.125mm Peak, 3 Mutually Perpendicular Axes,
1 Octave / Minute, 2 Hours In Each Axis.

Shock

In Accordance With MIL-STD 810G Method 516.7

Operational:
Half-sine, 15g, 25mS, 3 shocks in each direction of 3 mutually perpendicular axes

Survival (Operate After):
Half-sine, 20g, 23mS, 3 shocks in each direction of 3 mutually perpendicular axes

EMC

Emissions:
Conducted Emissions EN55032, A1, A2, Class B
Radiated Emissions EN55032, A1, A2, Class B

Immunity:
Electrostatic Discharge Immunity EN61000-4-2
Radiated RF Immunity EN61000-4-3
Transient Immunity EN61000-4-4
Surges EN61000-4-5
Conducted Immunity EN61000-4-6
AC Voltage Dips EN61000-4-11
Mains Harmonics EN61000-3-2

TEMPEST:
Products from this range have been designed to meet SDIP 27 Level B.